• Title of article

    The development of compressor-driven metal hydride heat pump (CDMHHP) system as an air conditioner

  • Author/Authors

    Park، نويسنده , , Jeong-Gun and Han، نويسنده , , Sang-Cheol and Jang، نويسنده , , Hwan-Yong and Lee، نويسنده , , Sangmin and Lee، نويسنده , , Paul S. and Lee، نويسنده , , Jai-Young، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    4
  • From page
    941
  • To page
    944
  • Abstract
    The compressor-driven metal hydride heat pump (CDMHHP) using commercialized oil-type compressor is built to demonstrate the practical applicability of metal hydride air-conditioning system. Extensive research has been carried out on the design, construction and operating performance of the system. The experimental results indicate that the present CDMHHP can produce a maximum cooling power of 353 kcal/kg-alloy h and an energy efficiency (COP) of 1.8 with a half-cycle time of 3 min. The minimum cooling temperature is 6°C at 7 Nm3/min airflow rate.
  • Keywords
    metal hydride , CDMHHP system , Compressor , COP , Cooling power
  • Journal title
    International Journal of Hydrogen Energy
  • Serial Year
    2002
  • Journal title
    International Journal of Hydrogen Energy
  • Record number