• Title of article

    A comparative study of chemical modifiers in the determination of total arsenic in marine food by tungsten coil electrothermal atomic absorption spectrometry

  • Author/Authors

    Bruhn، نويسنده , , Carlos G. and Bustos، نويسنده , , Catherine J. and Sلez، نويسنده , , Katia L. and Neira، نويسنده , , José Y. and Alvarez، نويسنده , , Solange E. Troupel، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2007
  • Pages
    9
  • From page
    81
  • To page
    89
  • Abstract
    Three platinum group elements (Pd, Ir and Rh) both in solution and in pre-reduced form, and also combined with Mg(NO3)2 or ascorbic acid, were assessed as possible chemical modifiers on the atomization of As in digest solutions of seafood matrices (clam and fish tissue) by tungsten coil electrothermal atomic absorption spectrometry (TCA-AAS) and compared without a modifier. Of 28 modifier alternatives in study including single form and binary mixtures, and based on maximum pyrolysis temperature without significant As loss and best As absorbance sensitivity during atomization, three modifiers: Rh (0.5 μg), Ir (1.0 μg) and Rh (0.5 μg) + ascorbic acid (0.5 μg), at optimum amounts were pre-selected and compared. The definitive modifier (rhodium (0.5 μg)) was selected by variance analysis. The mean within-day repeatability was 3% in consecutive measurements (25–300 μg l−1) (three cycles, each of n = 6) and showed good short-term stability of the absorbance measurements. The mean reproducibility was 4% (n = 18 in a 3-day period) and the detection limit (3σblank/slope) was 42 pg (n = 16). Quantitation was by standard additions to compensate for matrix effects not corrected by the modifier. Three sample digestion procedures were compared in fish and clam tissue samples: microwave acid digestion alone (A) or combined with the addition of 2% (m/v) K2S2O8 solution followed either by UV photo-oxidation (B) or re-digestion in a thermal block (C). The accuracy was established by determination of As in certified reference material of dogfish muscle (DORM-2). Procedures B and C showed good recoveries (102% (n = 4) and 103% (n = 7), respectively), whereas procedure A was not quantitative (85%). The methodology is simple, fast, reliable, of low cost and was applied to the determination of total As in lyophilized samples of clam and fish collected in the Chilean coast.
  • Keywords
    Arsenic , Tungsten coil electrothermal atomizer , Sample pretreatment , Lyophilized clam , Lyophilized fish , Chemical modifiers
  • Journal title
    Talanta
  • Serial Year
    2007
  • Journal title
    Talanta
  • Record number

    1651017