Title of article
Excitation-emission-kinetic fluorescence coupled with third-order calibration for quantifying carbaryl and investigating the hydrolysis in effluent water
Author/Authors
Zhu، نويسنده , , Shao-Hua and Wu، نويسنده , , Hai-Long and Xia، نويسنده , , A-Lin and Nie، نويسنده , , Jin-Fang and Bian، نويسنده , , Ying-Chao and Cai، نويسنده , , Chen-Bo and Yu، نويسنده , , Ru-Qin، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2009
Pages
7
From page
1640
To page
1646
Abstract
A novel method for determination of carbaryl in effluent was proposed in this study. The kinetic evolution of excitation-emission matrix fluorescence (EEM) for the pesticide were recorded and come into being a four-way data array. The four-way fluorescence data were analyzed using the parallel factor analysis (PARAFAC). The methodology exploits the second-order advantage of three-order calibration based on quadrilinear parallel factor analysis, allowing analyte concentrations to be estimated even in the presence of an uncalibrated fluorescent background. It gave the satisfactory results for determination of the carbaryl in effluent samples. In addition, the kinetic study of degradation of carbaryl was performed according to the kinetic profile provided by the calibration.
Keywords
Quadrilinear PARAFAC algorithm , Hydrolysis , carbaryl , Third-order calibration
Journal title
Talanta
Serial Year
2009
Journal title
Talanta
Record number
1656546