Title of article
Hydrogen storage in metal hydride tanks equipped with metal foam heat exchanger
Author/Authors
Mellouli، نويسنده , , S. and Dhaou، نويسنده , , H. and Askri، نويسنده , , F. and Jemni، نويسنده , , A. and Ben Nasrallah، نويسنده , , S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
9
From page
9393
To page
9401
Abstract
This paper presents a two-dimensional mathematical model to evaluate transient heat and mass transfer in a metal hydride tank (hereinafter MHT) with metal foam heat exchanger. The model is validated by comparison with experimental data. A good agreement is obtained.
y of the geometric and the operating parameters of the metal foam (such as base material, pore size and relative density) has been carried out to identify their influence on the performance of the charging process of the MHT. After that, the model was used as a tool to predict the performance of the hydrogen-charging process of two configurations of MHTs with metal foam heat exchangers. The obtained results showed that the reduction of the storage time due to the metal foam heat exchanger can be more important when the MHT is equipped with a concentric heat exchanger tube.
Keywords
Hydrogen storage , metal foams , Metal hydrides tank , Heat exchangers , Time charging
Journal title
International Journal of Hydrogen Energy
Serial Year
2009
Journal title
International Journal of Hydrogen Energy
Record number
1658559
Link To Document