• Title of article

    Optimization of carrier-mediated three-phase hollow fiber microextraction combined with HPLC-UV for determination of propylthiouracil in biological samples

  • Author/Authors

    Ebrahimzadeh، نويسنده , , Homeira and Asgharinezhad، نويسنده , , Ali Akbar and Abedi، نويسنده , , Hamid and Kamarei، نويسنده , , Fahimeh، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2011
  • Pages
    7
  • From page
    1043
  • To page
    1049
  • Abstract
    Carrier-mediated three-phase hollow fiber microextraction combined with high-performance liquid chromatography-ultra violet detection (HPLC-UV) was applied for the extraction and determination of propylthiouracil in biological samples. Propylthiouracil (PTU) was extracted from 7.5 mL of the basic solution (the source phase) with pH 12 into an organic phase (n-octanol containing 6% (w/v) of Aliquat 336 as the carrier) impregnated in the pores of a hollow fiber, and finally was back extracted into 24 μL of the acidic solution located inside the lumen of the hollow fiber (the receiving phase). The extraction was performed through the gradient of counter ion from the source to the receiving phase. The effects of different variables on the extraction efficiency were studied simultaneously using an experimental design. A half-fractional factorial design was employed for screening to determine the variables significantly affecting the extraction efficiency. Then, the factors with significant effect were optimized using a central composite design (CCD) and the response surface equations were developed. The optimal experimental conditions obtained from this statistical evaluation included: source phase, pH 12; temperature, 25 °C; extraction time, 40 min; counter ion concentration, 2 mol L−1 of NaClO4; organic solvent 6% of Aliquat in octanol and without salt addition in the source phase. Under the optimized conditions, the preconcentration factors were between 125 and 198 and also the limit of detections (LODs) ranged from 0.1 μg L−1 to 0.4 μg L−1 in different biological samples. The calibration curve was linear (r2 = 0.998) in the concentration range of 0.5–1000 μg L−1. Finally, the feasibility of the proposed method was successfully confirmed by extraction and determination of PTU in human plasma and urine as well as the bovine milk and meat samples in microgram per liter, and suitable results were obtained (RSDs < 6.3%).
  • Keywords
    Carrier-mediated , biological samples , Propylthiouracil , High Performance Liquid Chromatography , Three-phase hollow fiber microextraction
  • Journal title
    Talanta
  • Serial Year
    2011
  • Journal title
    Talanta
  • Record number

    1663011