Title of article
Micro-tubular, solid oxide fuel cell stack operated under single-chamber conditions
Author/Authors
Akhtar، نويسنده , , Naveed and Kendall، نويسنده , , Kevin، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
6
From page
13083
To page
13088
Abstract
A micro-tubular, solid oxide fuel cell stack has been developed and operated under single-chamber conditions. The stack, made of three single-cells, arranged in triangular configuration, was operated between 500 and 700 °C with varying methane/air mixtures. The results show that the operating conditions for the stack differ significantly than the single-cell operation reported in our earlier study. The stack operated at 600 °C with methane/oxygen mixture of 1.0 gives stable performance for up to 48 h, whereas for the single-cell, this mixing ratio was not suitable. The increase in the inert gas flow rate improves the stack performance up to a certain extent, beyond that; the power output by the stack reduces due to extensive dilution of the reactants. It is concluded that both, the operating conditions and the addition of inert gas, need to be tuned according to the number of cells present within the stack.
Keywords
Solid oxide fuel cell , Single-chamber , Inert gas , Micro-tubular , Stack
Journal title
International Journal of Hydrogen Energy
Serial Year
2011
Journal title
International Journal of Hydrogen Energy
Record number
1667793