In situ detection of anode flooding of a PEM fuel cell
Author/Authors
OʹRourke، نويسنده , , Judith and Ramani، نويسنده , , Manikandan and Arcak، نويسنده , , Murat، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
6
From page
6765
To page
6770
Abstract
This paper proposes an early detection scheme of anode flooding in a PEM fuel cell. Through experimental testing of an eight-cell hydrogen-fueled polymer electrolyte stack it is shown that anode flooding can be detected prior to a rapid voltage decline. The proposed detection scheme requires no additional costly instrumentation and uses the existing voltage scan cards.
oposed scheme requires that when the fuel cell is operating at low current densities, the current load is periodically spiked to a value of at least 0.5 A/cm2. During the spike the differences between the median cell voltage and the individual cellsʹ voltages are measured. If one or more cells significantly differ from the median anode flooding is suspected and corrective measures can be taken. Monitoring cell voltages at low current densities without spiking the load will not allow early detection of flooding. The proposed scheme is a simple, inexpensive method to lengthen the life of a fuel cell system.
Keywords
Fuel cell , Water management , Anode flooding