Title of article
Repair of shear-deficient and sulfate-damaged reinforced concrete beams using FRP composites
Author/Authors
Haddad، نويسنده , , R.H. and Al-Rousan، نويسنده , , R.Z. and Al-Sedyiri، نويسنده , , B.Kh.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
11
From page
228
To page
238
Abstract
Reinforced concrete structures often demonstrate nonstructural cracking caused by the action of sulfates from external sources. These cracks are signs of concrete damage that reduces the flexural and shear capacity of reinforced concrete structural elements and require therefore immediate attention. In this paper, the potential of using advanced composite materials in repairing shear deficient reinforced concrete prototype beams that are damaged by a sulfate cyclic treatment to a predetermined level is investigated. Prototype sulfate-damaged beams were repaired using varying configurations of (carbon and glass) fiber reinforced polymer (FRP) sheets or strips. Experimental data on shear strength capacity, stiffness, deflection, FRP strain, crack opening and mode of failure of the repaired beams were obtained, and compared with those of control, and sulfate-damaged ones. The results confirmed that FRP composites applied to shear spans not only enhanced the shear capacity but also improved deflection characteristics, stiffness, toughness, profitability index, crack resistance, performance factor, and FRP composites strain. However, the effectiveness of the present FRP repair schemes in terms of load capacity was negatively affected by the level of sulfate damage. Finally, a suitable analytical model was developed and examined for the prediction of FRP contribution to shear capacity of sulfate-damaged beams.
Keywords
Failures , Bond–slip , MODELING , Cyclic treatment , Beams , sulfate attack , FRP Composites , Repair
Journal title
Engineering Structures
Serial Year
2013
Journal title
Engineering Structures
Record number
1676289
Link To Document