• Title of article

    Determination of trace Cd, Cu, Fe, Pb and Zn in diesel and gasoline by inductively coupled plasma mass spectrometry after sample clean up with hollow fiber solid phase microextraction system

  • Author/Authors

    Philiswa N. Nomngongo، نويسنده , , Philiswa N. and Ngila، نويسنده , , J. Catherine، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    6
  • From page
    54
  • To page
    59
  • Abstract
    This study reports a simple and efficient method for the determination of trace Cd, Cu, Fe, Pb and Zn in diesel and gasoline samples by inductively coupled plasma mass spectrometry after matrix removal and analyte pre-concentration using hollow fiber-solid phase microextraction (HF–SPME). The optimization of HF-SPME procedure was carried out using two-level full factorial and central composite designs. Four factors (variables), that are, sample solution pH, acceptor phase amount, extraction time and eluent concentration were optimized. Under the optimized experimental conditions, the precision was ≤ 3% (C = 10 μg L− 1, n = 15), limits of detection and quantification ranged from 0.1 to 0.3 μg L− 1 and 0.3–0.9 μg L− 1, respectively, and the maximum preconcentration factor was 30. The HF-SPME method was applied for the determination of trace metals in real gasoline and diesel samples.
  • Keywords
    Gasoline , Trace metals , Hollow fiber-solid phase microextraction , diesel , Multivariate optimization
  • Journal title
    Spectrochimica Acta Part B Atomic Spectroscopy
  • Serial Year
    2014
  • Journal title
    Spectrochimica Acta Part B Atomic Spectroscopy
  • Record number

    1689174