Title of article
Residence times in fluidized beds with secondary gas injection
Author/Authors
Christensen، نويسنده , , D. and Nijenhuis، نويسنده , , J. and van Ommen، نويسنده , , J.R. and Coppens، نويسنده , , M.-O.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
11
From page
321
To page
331
Abstract
Experiments were carried out to determine the effects of secondary gas injection on the gas residence time and macromixing characteristics in a bubbling fluidized bed. Primary gas is introduced via a bottom distributor plate, while secondary gas is introduced via a fractal injector submerged in the bed. Results indicate that the average residence time decreases only slightly. Calculated overall reactor Péclet numbers indicate that the gas experiences less back-mixing with secondary gas injection. The bubble size was observed to decrease by up to 70%, indicating improved gas–solid contact. Taking this improved contact and plug flow behavior into account, the conversion in a fluidized bed with secondary gas injection is expected to increase significantly, particularly for mass-transfer limited reactions.
Keywords
fluidized bed , Residence time distribution , Fractal injector , Experimental method , Secondary injection
Journal title
Powder Technology
Serial Year
2008
Journal title
Powder Technology
Record number
1697239
Link To Document