• Title of article

    Influence of storage time on bond strength of self-etching adhesive systems to artificially demineralized dentin after a papain gel chemical–mechanical agent application

  • Author/Authors

    J. and Bridi، نويسنده , , Enrico Coser and Botelho Amaral، نويسنده , , Flلvia Lucisano and Gomes França، نويسنده , , Fabiana Mantovani and Martمo Flَrio، نويسنده , , Flلvia and Basting، نويسنده , , Roberta Tarkany Basting، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    7
  • From page
    31
  • To page
    37
  • Abstract
    Objectives m of this study was to evaluate the influence of storage time on the bond strength of self-etching adhesive systems to artificially demineralized dentin submitted to application of a papain-based chemical mechanical agent for carious tissue removal. als and Methods -four blocks of human coronal dentin were randomly divided into 2 groups: (1) restored with a two-step self-etching adhesive system (Clearfil SE Bond); (2) restored with a one-step self-etching adhesive system (One-Up Bond F Plus). After artificial caries induction, the specimens were treated with papain-based gel, received an application of the adhesive system according to the respective group, and blocks of microhybrid resin composite measuring 5.0 mm high and 5.0 mm wide were fabricated incrementally on the tooth, which would later be cut to obtain sticks with a bond area of around 1 mm2, for use in the microtensile tests. After this, half of the sticks obtained from each tooth were submitted to the microtensile test 24 h later, while the other half were stored in water, in an oven at 37° C for a period of 180 d. The specimens were submitted to the microtensile test in a Universal Test Machine at a speed of 0.5 mm/min. The surfaces of the fractured test specimens were examined visually under a stereoscopic loupe in order to classify the fracture type. After exploratory analysis of the data, the two-way Analysis of Variance (ANOVA) and the Tukey test were applied. The data on the fracture types were analyzed by the Exact Fisher test. s tistically relevant differences were verified among the means of the microtensile bond strength values of the adhesive systems evaluated in the different storage times. Mixed and adhesive fractures types were observed for both groups. sion e time did not influence the bond strength of the two-step or one-step self-etching adhesive systems to artificially demineralized dentin submitted to application of a papain-based chemical mechanical agent for carious tissue removal. Both adhesive systems provided similar bond strength at different storage times.
  • Keywords
    Surface treatment by chemical solutions , Adhesion by mechanical interlocking , Microtensile bond strength , Fracture mechanics
  • Journal title
    International Journal of Adhesion and Adhesives
  • Serial Year
    2012
  • Journal title
    International Journal of Adhesion and Adhesives
  • Record number

    1699822