• Title of article

    Gas and solid flow patterns in the loop-seal of a circulating fluidized bed

  • Author/Authors

    Bareschino، نويسنده , , Piero and Solimene، نويسنده , , Roberto and Chirone، نويسنده , , Riccardo and Salatino، نويسنده , , Piero، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    6
  • From page
    197
  • To page
    202
  • Abstract
    Gas and solid flow patterns in a loop-seal operated as solid re-injection device between the downcomer and the riser of a lab-scale cold CFB apparatus were characterized under a broad range of operating conditions by a combination of methods, including measurement of pressure time series along the CFB loop, solid mass flux along the riser and solids and gas tracing into the loop-seal. Analysis of results from solids and gas tracing tests highlights the role of both solid downflow in the supply chamber and gas cross-flow between the loop-seal chambers on the fluidization patterns. An approximate criterion is given for the onset of gas “leakage” between the two loop-seal sections, relevant to loop-seal applications in dual interconnected fluidized beds (DIFB).
  • Keywords
    Circulating fluidized bed , Loop seal , Non-mechanical valve
  • Journal title
    Powder Technology
  • Serial Year
    2014
  • Journal title
    Powder Technology
  • Record number