• Title of article

    Use of a respirometer to measure oxidation rates of polymeric materials at ambient temperatures

  • Author/Authors

    Assink، نويسنده , , Roger A. and Celina، نويسنده , , Mathew and Skutnik، نويسنده , , Julie M. and Harris، نويسنده , , Douglas J.، نويسنده ,

  • Issue Information
    دوهفته نامه با شماره پیاپی سال 2005
  • Pages
    7
  • From page
    11648
  • To page
    11654
  • Abstract
    The use of a respirometer is introduced as a novel technique for measuring the oxidation rates of thermally degrading polymers. A dual channel respirometer with fuel cell detectors demonstrates sufficient sensitivity to measure the oxidation rates of low-density polymeric samples at ambient temperatures in a relatively short period of time. Samples of low-density polyurethane foam were aged for various lengths of time in sealed chambers at temperatures ranging from 23 to 110 °C. The extent of oxygen depletion was measured by flushing the chamber with air and comparing the oxygen concentration in the chamber flow to that of a reference flow. Oxidation rates of the 0.1 g/cm3 polyurethane foam could be measured in less than 600 h of aging time at 23 °C. This corresponds to approximately 2 ppm oxidation by weight. Oxidation rates of the foam were used to calculate acceleration factors over a wide temperature range, including ambient conditions. Acceleration factors for the compressive force of the polyurethane foam were determined at elevated temperatures. Assuming that the aging behavior of compressive force of the foam is correlated to its oxidation rate, it is possible to calculate acceleration factors for the compressive force and predict the performance of the foam at ambient temperatures.
  • Keywords
    Oxidation Rate , respirometer , thermal degradation
  • Journal title
    Polymer
  • Serial Year
    2005
  • Journal title
    Polymer
  • Record number

    1724811