• Title of article

    Development of a multi-scale finite element model of the osteoporotic lumbar vertebral body for the investigation of apparent level vertebra mechanics and micro-level trabecular mechanics

  • Author/Authors

    McDonald، نويسنده , , Rashid K. and Little، نويسنده , , J. and Pearcy، نويسنده , , M. and Adam، نويسنده , , C.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    9
  • From page
    653
  • To page
    661
  • Abstract
    Osteoporotic spinal fractures are a major concern in ageing Western societies. This study develops a multi-scale finite element (FE) model of the osteoporotic lumbar vertebral body to study the mechanics of vertebral compression fracture at both the apparent (whole vertebral body) and micro-structural (internal trabecular bone core) levels. Model predictions were verified against experimental data, and found to provide a reasonably good representation of the mechanics of the osteoporotic vertebral body. This novel modelling methodology will allow detailed investigation of how trabecular bone loss in osteoporosis affects vertebral stiffness and strength in the lumbar spine.
  • Keywords
    Osteoporosis , Vertebral mechanics , Multi-scale model , Trabecular mechanics , Vertebral compression fracture , Finite element
  • Journal title
    Medical Engineering and Physics
  • Serial Year
    2010
  • Journal title
    Medical Engineering and Physics
  • Record number