• Title of article

    Evolved pseudo-wavelet function to optimally decompose sEMG for automated classification of localized muscle fatigue

  • Author/Authors

    Al-Mulla، نويسنده , , Mohamed R. and Sepulveda، نويسنده , , Francisco and Colley، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    7
  • From page
    411
  • To page
    417
  • Abstract
    The purpose of this study was to develop an algorithm for automated muscle fatigue detection in sports related scenarios. Surface electromyography (sEMG) of the biceps muscle was recorded from ten subjects performing semi-isometric (i.e., attempted isometric) contraction until fatigue. For training and testing purposes, the signals were labelled in two classes (Non-Fatigue and Fatigue), with the labelling being determined by a fuzzy classifier using elbow angle and its standard deviation as inputs. A genetic algorithm was used for evolving a pseudo-wavelet function for optimising the detection of muscle fatigue on any unseen sEMG signals. Tuning of the generalised evolved pseudo-wavelet function was based on the decomposition of twenty sEMG trials. After completing twenty independent pseudo-wavelet evolution runs, the best run was selected and then tested on ten previously unseen sEMG trials to measure the classification performance. Results show that an evolved pseudo-wavelet improved the classification of muscle fatigue between 7.31% and 13.15% when compared to other wavelet functions, giving an average correct classification of 88.41%.
  • Keywords
    localized muscle fatigue , sEMG , Wavelet analysis , Genetic algorithms
  • Journal title
    Medical Engineering and Physics
  • Serial Year
    2011
  • Journal title
    Medical Engineering and Physics
  • Record number

    1731254