Title of article
Numerical simulation of the fluid dynamics in vitreous cavity due to saccadic eye movement
Author/Authors
Abouali، نويسنده , , Omid and Modareszadeh، نويسنده , , Amirreza and Ghaffariyeh، نويسنده , , Alireza and Tu، نويسنده , , Jiyuan، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
12
From page
681
To page
692
Abstract
In this study, the flow dynamics of vitreous due to saccadic movements following vitreous liquefaction or in post-vitrectomy eyes is investigated. Using a dynamic mesh technique, the eye motion was modeled and unsteady three-dimensional forms of continuity and Navier–Stokes equations were solved numerically. Firstly, the numerical model was validated for a sphere as a model of vitreous chamber and agrees well with the results based on available analytic solutions and experimental data. Then, numerical simulation was performed based on a deformed sphere with an indentation representing the lens. This consists of a vitreous cavity filled with a liquid having the viscosity of liquefied vitreous and balanced salt solution. The wall shear stress on the retina was computed and compared for various saccade amplitudes. Also, the effect of variation in vitreous viscosity and the size of lens indentation are investigated. The results show that the secondary flow in the vertical direction in the vitreous cavity is much higher for the liquefied vitreous and balanced salt solution compared with that for silicone oil. The possible effect of shear stress on the retinal detachment for all studied cases is discussed. A semi-analytic correlation is also developed for maximum wall shear stress of the spherical domain that is subjected to sinusoidal rotations.
Keywords
Saccade , Vitreous , Eye , CFD , Shear stress , Retinal detachment , Spherical cavity
Journal title
Medical Engineering and Physics
Serial Year
2012
Journal title
Medical Engineering and Physics
Record number
1731673
Link To Document