• Title of article

    Prediction of Hypertension Improvement After Stenting of Renal Artery Stenosis: Comparative Accuracy of Translesional Pressure Gradients, Intravascular Ultrasound, and Angiography

  • Author/Authors

    Leesar، نويسنده , , Massoud A. and Varma، نويسنده , , Jai and Shapira، نويسنده , , Adam and Fahsah، نويسنده , , Ibrahim and Raza، نويسنده , , Seyed T. and Elghoul، نويسنده , , Ziad and Leonard، نويسنده , , Anthony C. and Meganathan، نويسنده , , Karthikeyan and Ikram، نويسنده , , Sohail، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    9
  • From page
    2363
  • To page
    2371
  • Abstract
    Objectives estigated the comparative accuracy of renal translesional pressure gradients (TPG), intravascular ultrasound (IVUS), and angiographic parameters in predicting hypertension improvement after stenting of renal artery stenosis (RAS). ound gree of RAS that justifies stenting is unknown. s patients with RAS, TPG (resting and hyperemic systolic gradient [HSG], fractional flow reserve, and mean gradient) were measured by a pressure guidewire; IVUS and angiographic parameters (minimum lumen area and diameter, area stenosis, and diameter stenosis) were measured by quantitative analyses. s G had a larger area under the curve than most other parameters and an HSG ≥21 mm Hg had the highest sensitivity, specificity, and accuracy (82%, 84%, and 84%, respectively) in predicting hypertension improvement after stenting of RAS. The average IVUS area stenosis was markedly greater in RAS with an HSG ≥21 mm Hg versus <21 mm Hg (78% vs. 38%, respectively; p < 0.001). After stenting, hypertension improved in 84% of patients with an HSG ≥21 mm Hg (n = 36) versus 36% of patients with an HSG <21 mm Hg (n = 26) at 12 months, p < 0.01; the number of antihypertensive medications was significantly lower in patients with an HSG ≥21 mm Hg versus <21 mm Hg (2.30 ± 0.90 vs. 3.40 ± 0.50, respectively; p < 0.01). By multivariable analysis, HSG was the only independent predictor of hypertension improvement (odds ratio: 1.39; 95% confidence interval: 1.05 to 1.65; p = 0.013). sions ≥21 mm Hg provided the highest accuracy in predicting hypertension improvement after stenting of RAS, suggesting that an HSG ≥21 mm Hg is indicative of significant RAS.
  • Keywords
    Renal Artery stenosis , renal translesional pressure gradients , intravascular ultrasound , angiography
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2009
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number