• Title of article

    Geometry and Degree of Apposition of the CoreValve ReValving System With Multislice Computed Tomography After Implantation in Patients With Aortic Stenosis

  • Author/Authors

    Schultz، نويسنده , , Carl J. and Weustink، نويسنده , , Annick and Piazza، نويسنده , , Nicolo and Otten، نويسنده , , Amber and Mollet، نويسنده , , Nico and Krestin، نويسنده , , Gabriel and van Geuns، نويسنده , , Robert J. and de Feyter، نويسنده , , Pim and Serruys، نويسنده , , Patrick W.J. and de Jaegere، نويسنده , , Peter، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    8
  • From page
    911
  • To page
    918
  • Abstract
    Objectives multislice computed tomography (MSCT), we sought to evaluate the geometry and apposition of the CoreValve ReValving System (CRS, Medtronic, Luxembourgh, Luxembourgh) in patients with aortic stenosis. ound are no data on the durability of percutaneous aortic valve replacement. Geometric factors may affect durability. s patients had MSCT at a median 1.5 months (interquartile range [IQR] 0 to 7 months) after percutaneous aortic valve replacement. Axial dimensions and apposition of the CRS were evaluated at 4 levels: 1) the ventricular end; 2) the nadir; 3) central coaptation of the CRS leaflets; and 4) commissures. Orthogonal smallest and largest diameters and cross-sectional surface area were measured at each level. s S (26-mm: n = 14, 29-mm: n = 16) was implanted at 8.5 mm (IQR 5.2 to 11.0 mm) below the noncoronary sinus. None of the CRS frames reached nominal dimensions. The difference between measured and nominal cross-sectional surface area at the ventricular end was 1.6 cm2 (IQR 0.9 to 2.6 cm2) and 0.5 cm2 (IQR 0.2 to 0.7 cm2) at central coaptation. At the level of central coaptation the CRS was undersized relative to the native annulus by 24% (IQR 15% to 29%). The difference between the orthogonal smallest and largest diameters (degree of deformation) at the ventricular end was 4.4 mm (IQR 3.3 to 6.4 mm) and it decreased progressively toward the outflow. Incomplete apposition of the CRS frame was present in 62% of patients at the ventricular end and was ubiquitous at the central coaptation and higher. sions ource MSCT demonstrated incomplete and nonuniform expansion of the CRS frame, but the functionally important mid-segment was well expanded and almost symmetrical. Undersizing and incomplete apposition were seen in the majority of patients.
  • Keywords
    Cardiac computed tomography , percutaneous valve replacement , aortic valve
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2009
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    1745402