• Title of article

    The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial: The Value of Wireless Remote Monitoring With Automatic Clinician Alerts

  • Author/Authors

    Crossley، نويسنده , , George H. and Boyle، نويسنده , , Andrew and Vitense، نويسنده , , Holly and Chang، نويسنده , , Yanping and Mead، نويسنده , , R. Hardwin، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    9
  • From page
    1181
  • To page
    1189
  • Abstract
    Objectives imary objective was to determine if wireless remote monitoring with automatic clinician alerts reduces the time from a clinical event to a clinical decision in response to arrhythmias, cardiovascular (CV) disease progression, and device issues compared to patients receiving standard in-office care. A secondary objective was to compare the rates of CV health care utilization between patients in the remote and in-office arms. ound ition to providing life-saving therapy, implantable cardioverter-defibrillators collect advanced diagnostics on the progression of the patientʹs heart disease. Device technology has progressed to allow wireless remote monitoring with automatic clinician alerts to replace some scheduled in-office visits. s NNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) study was a multicenter, prospective, randomized evaluation involving 1,997 patients from 136 clinical sites who underwent insertion of an implantable cardioverter-defibrillator (including cardiac resynchronization therapy devices) and were followed up for 15 months. Health care utilization data included all CV-related hospitalizations, emergency department visits, and clinic office visits. s dian time from clinical event to clinical decision per patient was reduced from 22 days in the in-office arm to 4.6 days in the remote arm (p < 0.001). The health care utilization data revealed a decrease in mean length of stay per CV hospitalization visit from 4.0 days in the in-office arm to 3.3 days in the remote arm (p = 0.002). sions ss remote monitoring with automatic clinician alerts as compared with standard in-office follow-up significantly reduced the time to a clinical decision in response to clinical events and was associated with a significant reduction in mean length of CV hospital stay. (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision [CONNECT]; NCT00402246)
  • Keywords
    clinician notification , health care economics , cardiac resynchronization therapy , remote patient monitoring , implantable cardioverter-defibrillator , alerts
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2011
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    1751692