Banerjee، نويسنده , , Subhash and Das، نويسنده , , Tony S. and Abu-Fadel، نويسنده , , Mazen S. and Dippel، نويسنده , , Eric J. and Shammas، نويسنده , , Nicolas W. and Tran، نويسنده , , Daniel L. and Zankar، نويسنده , , Ahmad and Varghese، نويسنده , , Cyril and Kelly، نويسنده , , Kevin C. and Weideman، نويسنده , , Rick A. and Little، نويسنده , , Bertis B. and Reilly، نويسنده , , Robert F. and Addo، نويسنده , , Tayo and Brilakis، نويسنده , , Emmanouil S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
8
From page
1352
To page
1359
Abstract
Objectives
rpose of this study is to compare post-dilation strategies of nitinol self-expanding stents implanted in the superficial femoral artery of diabetic patients with peripheral arterial disease.
ound
scular treatment of superficial femoral artery disease with nitinol self-expanding stents is associated with high rates of in-stent restenosis in patients with diabetes mellitus.
s
ducted a prospective, multicenter, randomized, controlled clinical trial of diabetic patients to investigate whether post-dilation of superficial femoral artery nitinol self-expanding stents using a cryoplasty balloon reduces restenosis compared to a conventional balloon. Inclusion criteria included diabetes mellitus, symptomatic peripheral arterial disease, and superficial femoral artery lesions requiring implantation of stents >5 mm in diameter and >60 mm in length. Primary endpoint was binary restenosis at 12 months, defined as ≥2.5-fold increase in peak systolic velocity by duplex ultrasonography.
s
y-four patients, with 90 stented superficial femoral artery lesions, were randomly assigned to post-dilation using cryoplasty (n = 45 lesions) or conventional balloons (n = 45 lesions). Mean lesion length was 148 ± 98 mm, mean stented length was 190 ± 116 mm, mean stent diameter was 6.1 ± 0.4 mm, and 50% of the lesions were total occlusions. Post-dilation balloon diameters were 5.23 ± 0.51 mm versus 5.51 ± 0.72 mm in the cryoplasty and conventional balloon angioplasty groups, respectively (p = 0.02). At 12 months, binary restenosis was significantly lower in the cryoplasty group (29.3% vs. 55.8%, p = 0.01; odds ratio: 0.36, 95% confidence interval: 0.15 to 0.89).
sions
diabetic patients undergoing implantation of nitinol self-expanding stents in the superficial femoral artery, post-dilation with cryoplasty balloon reduced binary restenosis compared to conventional balloon angioplasty. (Study Comparing Two Methods of Expanding Stents Placed in Legs of Diabetics With Peripheral Vascular Disease [COBRA]; NCT00827853)
Keywords
cryoplasty , diabetes mellitus , superficial femoral artery , peripheral arterial disease