• Title of article

    Effects of cell volume fraction changes on apparent diffusion in human cells

  • Author/Authors

    Anderson، نويسنده , , A.W and Xie، نويسنده , , J and Pizzonia، نويسنده , , Richard A. Bronen، نويسنده , , Jonathan R.A. and Spencer، نويسنده , , D.D and Gore، نويسنده , , J.C، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    7
  • From page
    689
  • To page
    695
  • Abstract
    Diffusion-weighted imaging was used to study the relationship between apparent diffusion coefficient (ADC) and cell volume fraction in cell suspensions and packed arrays. Cell volume fraction was varied by changing extracellular fluid osmolarity (for human glial cells) and by changing cell density (for human glial and red blood cells). In packed arrays of glial cells, ADC increased 10% when cells shrank and decreased 13% when cells swelled. ADC decreased 34% as cell density increased from 0 to 72%. In erythrocyte suspensions, ADC decreased 90% as the cell density increased from 0 to 89%. These results agree with theoretical predictions.
  • Keywords
    Apparent diffusion coefficient , Cell volume fraction , astrocytes , Erythrocytes
  • Journal title
    Magnetic Resonance Imaging
  • Serial Year
    2000
  • Journal title
    Magnetic Resonance Imaging
  • Record number