• Title of article

    Complex-valued wavelet artificial neural network for Doppler signals classifying

  • Author/Authors

    ?zbay، نويسنده , , Yüksel and Kara، نويسنده , , Sad?k and Latifo?lu، نويسنده , , Fatma and Ceylan، نويسنده , , Rahime and Ceylan، نويسنده , , Murat، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    14
  • From page
    143
  • To page
    156
  • Abstract
    SummaryObjective s paper, the new complex-valued wavelet artificial neural network (CVWANN) was proposed for classifying Doppler signals recorded from patients and healthy volunteers. CVWANN was implemented on four different structures (CVWANN-1, -2, -3 and -4). als and methods s study, carotid arterial Doppler ultrasound signals were acquired from left carotid arteries of 38 patients and 40 healthy volunteers. The patient group had an established diagnosis of the early phase of atherosclerosis through coronary or aortofemoropopliteal angiographies. In implemented structures in this paper, Haar wavelet and Mexican hat wavelet functions were used as real and imaginary parts of activation function on different sequence in hidden layer nodes. CVWANN-1, -2 -3 and -4 were implemented by using Haar-Haar, Mexican hat-Mexican hat, Haar-Mexican hat, Mexican hat-Haar as real-imaginary parts of activation function in hidden layer nodes, respectively. s and conclusion trast to CVWANN-2, which reached classification rates of 24.5%, CVWANN-1, -3 and -4 classified 40 healthy and 38 unhealthy subjects for both training and test phases with 100% correct classification rate using leave-one-out cross-validation. These networks have 100% sensitivity, 100% specifity and average detection rate is calculated as 100%. In addition, positive predictive value and negative predictive value were obtained as 100% for these networks. These results shown that CVWANN-1, -3 and -4 succeeded to classify Doppler signals. Moreover, training time and processing complexity were decreased considerable amount by using CVWANN-3. clusion, using of Mexican hat wavelet function in real and imaginary parts of hidden layer activation function (CVWANN-2) is not suitable for classifying healthy and unhealthy subjects with high accuracy rate. The cause of unsuitability (obtaining the poor results in CVWANN-2) is lack of harmony between type of activation function in hidden layer and type of input signals in neural network.
  • Keywords
    carotid artery , Doppler signals , Complex-valued wavelet artificial neural network , Wavelet neural network , atherosclerosis , Leave-one-out cross-validation
  • Journal title
    Artificial Intelligence In Medicine
  • Serial Year
    2007
  • Journal title
    Artificial Intelligence In Medicine
  • Record number