Title of article
Validation of an externally oil-cooled 1 kWel HT-PEMFC stack operating at various experimental conditions
Author/Authors
Bujlo، نويسنده , , P. and Pasupathi، نويسنده , , S. and Ulleberg، نويسنده , , ط. and Scholta، نويسنده , , J. and Nomnqa، نويسنده , , M.V. and Rabiu، نويسنده , , Gregory A. and Pollet، نويسنده , , B.G.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
9
From page
9847
To page
9855
Abstract
The performance of 1 kWel 48-cell HT-PEMFC at various experimental conditions is presented, particularly at several CO concentrations (up to 1.0%). Polarization curves measured at various anode (1.0–2.5) and cathode (1.6–4.0) stoichiometries; stack operating temperatures (120–160 °C) and gas pressures (up to 0.5 barg) are reported and analysed. The minimum gas stoichiometries of 1.25 and 2.0 were determined for the anode and cathode, respectively. The highest stack power density of 225 mW cm−2 was measured at 160 °C and 0.4 A cm−2. Operation at CO concentrations up to 1% was achieved, although a loss of performance of about 4% was observed for low CO concentrations. The operating temperature enhanced fuel cell performance and tolerance to CO, even when supplied with higher CO concentration in the anode feed gas.
Keywords
HT-PEMFC , fuel cell stack , Performance , CO tolerance , Externally cooled
Journal title
International Journal of Hydrogen Energy
Serial Year
2013
Journal title
International Journal of Hydrogen Energy
Record number
1863913