• Title of article

    Mechanical environment of the supraspinatus tendon: a two-dimensional finite element model analysis

  • Author/Authors

    Wakabayashi، نويسنده , , Ikuko and Itoi، نويسنده , , Eiji and Sano، نويسنده , , Hirotaka and Shibuya، نويسنده , , Yotsugi and Sashi، نويسنده , , Ryuji and Minagawa، نويسنده , , Hiroshi and Kobayashi، نويسنده , , Moto، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    6
  • From page
    612
  • To page
    617
  • Abstract
    We performed 2-dimensional finite element model analysis to estimate the mechanical environment of the supraspinatus tendon. The geometric shape of the finite element model was determined by magnetic resonance imaging of a normal human shoulder obtained at 0°, 30°, and 60° of abduction, whereas the histologic location of noncalcified and calcified fibrocartilage was determined from a cadaveric specimen. The supraspinatus tendon was pulled proximally with the force of 10 N at 0°, 53 N at 30°, and 115 N at 60° of abduction. The area of high principal stress maximum was observed on the articular side of the supraspinatus tendon, which shifted toward the insertion as the arm was abducted. High stress concentration on the articular side of the supraspinatus tendon near its insertion during arm elevation may explain the frequent occurrence of rotator cuff tears at this site.
  • Journal title
    Journal of Shoulder and Elbow Surgery
  • Serial Year
    2003
  • Journal title
    Journal of Shoulder and Elbow Surgery
  • Record number

    1866241