• Title of article

    CFD model performance benchmark of fast filling simulations of hydrogen tanks with pre-cooling

  • Author/Authors

    Melideo، نويسنده , , Daniele and Baraldi، نويسنده , , Daniele and Galassi، نويسنده , , Maria Cristina and Ortiz Cebolla، نويسنده , , Rafael and Acosta Iborra، نويسنده , , Beatriz and Moretto، نويسنده , , Pietro، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    7
  • From page
    4389
  • To page
    4395
  • Abstract
    High gas temperatures can be reached inside a hydrogen tank during the filling process because of the large pressure increase (up to 70–80 MPa) and because of the short time (∼3 min) of the process. High temperatures can potentially jeopardize the structural integrity of the storage system and one of the strategies to reduce the temperature increase is to pre-cool the hydrogen before injecting it into the tank. Computational Fluid Dynamics (CFD) tools have the capabilities of capturing the flow field and the temperature rise in the tank. The results of CFD simulations of fast filling with pre-cooling are shown and compared with experimental data to assess the accuracy of the CFD model.
  • Keywords
    Storage , Fast filling , Hydrogen , Safety , CFD
  • Journal title
    International Journal of Hydrogen Energy
  • Serial Year
    2014
  • Journal title
    International Journal of Hydrogen Energy
  • Record number

    1867675