Title of article
Hydrogen-induced cracking and service safety evaluation for precipitation strengthened austenitic stainless steel as hydrogen storage tank
Author/Authors
Yan، نويسنده , , Yingjie and Yan، نويسنده , , Yu and He، نويسنده , , Yang and Li، نويسنده , , Jinxu and Su، نويسنده , , Yanjing and Qiao، نويسنده , , Lijie، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
8
From page
17921
To page
17928
Abstract
The safety of precipitation strengthened austenitic stainless steels used for hydrogen storage tanks is of great interest. However, their application may face hydrogen damage resulting in hydrogen-induced delayed failure. Results show that over-loading and hydrogen-induced failure always occur at the weld part of the alloy. Hydrogen damage such as microcracks could be observed on the surface of the matrix and the weld during charging even without any applied stress. Hydrogen-induced failure occurred during charging under constant load and the normalized threshold stress decreased exponentially with increasing defined time tc. It is shown that the threshold stress with no hydrogen-induced failure occurring for expected service life, i.e. forty years, was 713 MPa. Therefore under the service stress, which is less than the threshold stress, 713 MPa, the safety factor of the hydrogen storage tank for hydrogen-induced fracture is great enough to indicate the tank to last for the entire designed service time.
Keywords
Precipitation strengthened austenitic stainless steel , Hydrogen damage , Hydrogen-induced failure , Hydrogen storage tank
Journal title
International Journal of Hydrogen Energy
Serial Year
2014
Journal title
International Journal of Hydrogen Energy
Record number
1870450
Link To Document