• Title of article

    Power Consumption Minimization of Khormoj Compressor Station

  • Author/Authors

    Haddad، Javid نويسنده National Iranian Oil Company (NIOC), Pars Oil and Gas Company (POGC), South Pars Gas Field Development Phases 17&18, Assaluye, Iran Haddad, Javid , Mosayebi Behbahani، Reza نويسنده Department of Gas Engineering, Petroleum University of Technology, Ahwaz, Iran Mosayebi Behbahani, Reza , Shishesaz، Mohammadreza نويسنده Department of Technical Inspection Engineering, Petroleum University of Technology, Abadan, Iran Shishesaz, Mohammadreza

  • Issue Information
    فصلنامه با شماره پیاپی 7 سال 2014
  • Pages
    14
  • From page
    66
  • To page
    79
  • Abstract
    Arguably, the natural gas transmission pipeline infrastructure in Iran represents one of the largest and most complex mechanical systems in the world. The optimization of large gas trunk lines known as IGAT results in reduced fuel consumption or higher capability and improves pipeline operation. In the current study, a single-objective optimization was conducted for Khormoj compressor station on the Iranian gas trunk line V (IGAT5). The system consists of over 504 kilometers of 56-inch pipeline from South Pars to Aghajari. This system passes through a tortuous terrain with changes in elevation which makes the optimization process even more challenging. Genetic algorithm (GA) was used in this optimization along with detailed models of the performance characteristics of compressors. The results show that in stations having the same compressor in parallel the minimum power (energy) consumption is reached when split flow in all the compressors is the same.
  • Journal title
    Iranian Journal of Oil and Gas Science and Technology(IJOGST)
  • Serial Year
    2014
  • Journal title
    Iranian Journal of Oil and Gas Science and Technology(IJOGST)
  • Record number