Title of article
Safety and Effectiveness of Placement of Pacemaker and Defibrillator Leads in the Axillary Vein Guided by Contrast Venography
Author/Authors
Ramza MD، نويسنده , , PhD، نويسنده , , Brian CM and Rosenthal MD، نويسنده , , PhD، نويسنده , , Lawrence and Hui MD، نويسنده , , PhD، نويسنده , , Richard and Nsah MD، نويسنده , , Emmanuel and Savader MD، نويسنده , , Scott and Lawrence MD، نويسنده , , John H and Tomaselli MD، نويسنده , , Gordon and Berger MD، نويسنده , , PhD، نويسنده , , Ronald and Brinker MD، نويسنده , , Jeffrey and Calkins MD، نويسنده , , Hugh، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1997
Pages
5
From page
892
To page
896
Abstract
Despite evidence of an increased incidence of lead fracture, the infraclavicular subclavian approach remains the dominant approach for placement of pacemaker and implantable defibrillator leads. Although this complication can be prevented by lead placemen
Journal title
American Journal of Cardiology
Serial Year
1997
Journal title
American Journal of Cardiology
Record number
1886400
Link To Document