• Title of article

    Experimental study of convective heat transfer from in-line cam shaped tube bank in crossflow

  • Author/Authors

    Mirabdolah Lavasani، نويسنده , , Arash and Bayat، نويسنده , , Hamidreza and Maarefdoost، نويسنده , , Taher، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    9
  • From page
    85
  • To page
    93
  • Abstract
    Heat transfer from cam-shaped tube bank has been studied experimentally. Tubes were mounted in an in-line arrangement with two longitudinal pitch ratios 1.5 and 2. Reynolds number based on equivalent diameter varied in range of 27,000 ≤ ReD ≤ 42,500. Drag coefficient and heat transfer from tubes in second row were obtained. Results show that drag coefficient and heat transfer of cam shaped tubes depend on position of tubes in tube bank. Tubes that located at first and second column have the maximum and minimum value of drag coefficient, respectively. In addition, Heat transfer from subsequent tubes is greater than tube in first column. Thermal hydraulic performance of cam shape tube is about 6 times greater than circular tube with same equivalent diameter.
  • Keywords
    Experimental , heat transfer , CrossFlow , Tube Bank , Cam shaped
  • Journal title
    Applied Thermal Engineering
  • Serial Year
    2014
  • Journal title
    Applied Thermal Engineering
  • Record number

    1906850