Title of article
Experimental study of convective heat transfer from in-line cam shaped tube bank in crossflow
Author/Authors
Mirabdolah Lavasani، نويسنده , , Arash and Bayat، نويسنده , , Hamidreza and Maarefdoost، نويسنده , , Taher، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
9
From page
85
To page
93
Abstract
Heat transfer from cam-shaped tube bank has been studied experimentally. Tubes were mounted in an in-line arrangement with two longitudinal pitch ratios 1.5 and 2. Reynolds number based on equivalent diameter varied in range of 27,000 ≤ ReD ≤ 42,500. Drag coefficient and heat transfer from tubes in second row were obtained. Results show that drag coefficient and heat transfer of cam shaped tubes depend on position of tubes in tube bank. Tubes that located at first and second column have the maximum and minimum value of drag coefficient, respectively. In addition, Heat transfer from subsequent tubes is greater than tube in first column. Thermal hydraulic performance of cam shape tube is about 6 times greater than circular tube with same equivalent diameter.
Keywords
Experimental , heat transfer , CrossFlow , Tube Bank , Cam shaped
Journal title
Applied Thermal Engineering
Serial Year
2014
Journal title
Applied Thermal Engineering
Record number
1906850
Link To Document