Normalized performance parameters for a residential heat pump in the cooling mode with single faults imposed
Author/Authors
Cho، نويسنده , , Jin Min and Heo، نويسنده , , Jaehyeok and Payne، نويسنده , , W. Vance and Domanski، نويسنده , , Piotr A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
15
From page
1
To page
15
Abstract
The cooling mode performance of a residential split heat pump operating under nine different faults was described using normalized performance parameters determined from a ratio of the fault value to the no-fault value obtained from heat pump tests in environmental chambers. The normalized parameters were the coefficient of performance (COP), total capacity, refrigerant-side capacity, sensible heat ratio, outdoor unit power, and total power. A correlation for the normalized performance parameters was developed to produce a continuous representation of the performance characteristics given the fault level and indoor and outdoor temperature conditions.
Keywords
Air conditioner , Fault detection , Heat pump