Title of article
Obstructed airflow through the condenser of an automotive air conditioner – Effects on the condenser and the overall performance of the system
Author/Authors
Datta، نويسنده , , S.P. and Das، نويسنده , , P.K. and Mukhopadhyay، نويسنده , , S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
10
From page
925
To page
934
Abstract
The performance of a cross-flow, microchannel condenser of an automotive air conditioning system (AACS) subjected to the maldistribution of airflow has been studied experimentally. The maldistribution of airflow has been created by placing different upstream screens with uniform, middle, side or peripheral block having 30%, 40% or 50% area blockage and a total of 52 set of experiments were conducted over a wide range of parameters. Infrared imaging was used to assess the deterioration of condenser cooling under blocked condition. Though there has been a significant reduction of the performance of the condenser, the refrigerant flow was observed to increase with the increase of area of blockage. The cooling capacity and COP of the system decreased by 8.16% and 16.8% respectively for an area blockage of 50% compared to the normal operating condition. Effect of side and middle blockage were noted to be more severe while, the peripheral blockage had a minimum effect.
Keywords
Automotive air conditioning , Condenser , Air maldistribution , Mass flow rate , Blockage , COP
Journal title
Applied Thermal Engineering
Serial Year
2014
Journal title
Applied Thermal Engineering