• Title of article

    Removal and recycling of pollutants from Hong Kong restaurant wastewaters

  • Author/Authors

    Chan، نويسنده , , H.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    9
  • From page
    6859
  • To page
    6867
  • Abstract
    Most restaurant operators in Hong Kong run their business in commercial buildings. Many of them fail to meet oil and grease (O & G) limits. The O & G and Chemical Oxygen Demand (COD) content of the effluents can be reduced to meet government prescribed standards using a combination of compressed air and chemical treatment in existing two-chamber grease traps. A mean level of 41 mg/L and a mean removal of 92.7% of O & G can be achieved for a typical fast food restaurant. COD reduction can further be improved by dissolved air flotation enhanced with chemicals. Sludge generated from flotation treatment of the wastewaters can be recycled as a fertilizer to give a mean total nitrogen content of 13,217 mg/kg and a mean total phosphorus level of 1133 mg/kg. Moreover, it can also be utilized as a biofuel to give a mean calorific value of 6690 Cal/g which is equivalent to that of coal.
  • Keywords
    G , fertilizer , Restaurant effluent , biofuel , COD , O &
  • Journal title
    Bioresource Technology
  • Serial Year
    2010
  • Journal title
    Bioresource Technology
  • Record number