• Title of article

    Validation of a method of high performance liquid chromatography with fluorescence detection for melamine determination in UHT whole bovine milk

  • Author/Authors

    de Lourdes Mendes Finete، نويسنده , , Virgيnia de Lourdes Mendes and Gouvêa، نويسنده , , Marcos Martins and Marques، نويسنده , , Flلvia Ferreira de Carvalho and Pereira Netto، نويسنده , , Annibal Duarte، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2015
  • Pages
    6
  • From page
    402
  • To page
    407
  • Abstract
    A method of high performance liquid chromatography with fluorescence detection (HPLC-Fluo), based on previous studies of the natural fluorescence emission of melamine (250/365 nm), was developed and validated for melamine determination as an adulterant of bovine UHT whole milk. The clean up treatment of milk samples by deproteinization was thoroughly optimized. No matrix effect was observed and a linear range from 0.05 to 10.0 μg mL−1 was obtained, with a value of R2 equal to 0.9998. The limits of detection and quantification of melamine were 0.0081 and 0.027 μg mL−1 respectively, or 0.023 and 0.076 μg g−1 of milk, respectively, considering the sample dilution during extraction. Extracts of milk samples fortified with melamine at three concentration levels, two of which corresponded to the levels established by WHO for melamine in foods, led to an overall mean recovery of 95.4 ± 1.2% (n = 9). This recovery value satisfies the performance criteria established by the Codex Alimentarius for analytical methods suitable for determination of food residues, demonstrating the usefulness and effectiveness of the proposed method.
  • Keywords
    UHT whole bovine milk , Natural fluorescence of melamine , Milk adulteration , Melamine determination , HPLC-fluorescence detection
  • Journal title
    Food Control
  • Serial Year
    2015
  • Journal title
    Food Control
  • Record number

    1950907