• Title of article

    A novel chemiluminescence sensor for determination of quercetin based on molecularly imprinted polymeric microspheres

  • Author/Authors

    Qiu، نويسنده , , Huamin and Luo، نويسنده , , Chuannan and Sun، نويسنده , , Min and Lu، نويسنده , , Fuguang and Fan، نويسنده , , Lulu and Li، نويسنده , , Xiangjun، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    5
  • From page
    469
  • To page
    473
  • Abstract
    A novel flow injection chemiluminescence (FI-CL) sensor for determination of quercetin using the system of luminol-NaOH–H2O2 based on molecularly imprinted polymeric microspheres (MIPm) as recognition element is established. The quercetin MIPm was synthesised by precipitation polymerisation using acetone as solvent, acrylamide (AM) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linker and 2,2-azobisisobutyronitrile (AIBN) as initiator. And the polymers’ properties were characterised. The FI-CL optimised experimental were obtained and the possible mechanism was discussed. The CL intensity responded linearly to the concentration of quercetin ranged from 1.4 × 10−6 to 1.6 × 10−4 mol/L with a detection limit of 9.3 × 10−7 mol/L (3σ). The relative standard deviation (RSD) for determination was ranged from 2.72% to 3.31%. On the basis of speediness and sensitivity, the sensor is reusable and has a great improvement in selectivity. As a result, the new sensor had been successfully applied to the determination of quercetin in drug samples.
  • Keywords
    Molecularly imprinted polymeric microspheres , Flow Injection , Quercetin , Chemiluminescence
  • Journal title
    Food Chemistry
  • Serial Year
    2012
  • Journal title
    Food Chemistry
  • Record number