• Title of article

    Electrochemical determination of bisphenol A in plastic bottled drinking water and canned beverages using a molecularly imprinted chitosan–graphene composite film modified electrode

  • Author/Authors

    Deng، نويسنده , , Peihong and Xu، نويسنده , , Zhifeng and Kuang، نويسنده , , Yunfei، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    8
  • From page
    490
  • To page
    497
  • Abstract
    Herein, a novel electrochemical sensor based on an acetylene black paste electrode modified with molecularly imprinted chitosan–graphene composite film for sensitive and selective detection of bisphenol A (BPA) has been developed. Several important parameters controlling the performance of the sensor were investigated and optimised. The imprinted sensor offers a fast response and sensitive BPA quantification. Under the optimal conditions, a linear range from 8.0 nM to 1.0 μM and 1.0 to 20 μM for the detection of BPA was observed with the detection limit of 6.0 nM (S/N = 3). Meanwhile, the fabricated sensor showed excellent specific recognition to template molecule among the structural similarities and coexistence substances. Furthermore, this imprinted electrochemical sensor was successfully employed to detect BPA in plastic bottled drinking water and canned beverages.
  • Keywords
    Imprinted electrochemical sensor , graphene , Chitosan , Voltammetric determination , Composite film , BISPHENOL A
  • Journal title
    Food Chemistry
  • Serial Year
    2014
  • Journal title
    Food Chemistry
  • Record number

    1977944