• Title of article

    Sublethal effects of a chlorinated and heated effluent on the physiology of the mussel, Mytilus edulis L.: A reduction in fitness for survival?

  • Author/Authors

    Mazik، نويسنده , , Krysia and Hitchman، نويسنده , , Natasha and Quintino، نويسنده , , Victor and Taylor، نويسنده , , Colin J.L. and Butterfield، نويسنده , , Jonathan and Elliott، نويسنده , , Michael، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    9
  • From page
    123
  • To page
    131
  • Abstract
    Coastal power stations entrain large volumes of cooling water, requiring biocidal treatment to prevent biological fouling. Discharged effluent is both heated and contaminated with residual traces of biocide and so it is necessary to quantify the impacts of this discharge. Cooling water from Heysham 2 nuclear power station, NW England, UK, is discharged to the intertidal area, via a culvert (to minimise erosion and maximise dilution and dispersion by directing the effluent into the receiving water at all states of the tide) within which the effluent is contained at low water. The culvert and surrounding coastal area support a population of blue mussels (Mytilus edulis). Mussel health was determined along a gradient of exposure, using three physiological indices: Scope for Growth, Gonad Mantle Index and Somatic Condition Index (K Factor). The Mussels within the culvert exhibited reduced physiological index values compared to an external site. A trend was identified down the length of the culvert, representing a gradient of exposure and indicating a potential negative effect on growth and reproductive output.
  • Keywords
    Somatic condition indices , Mytilus edulis , Chlorination , Scope for growth , Macrofouling
  • Journal title
    Marine Pollution Bulletin
  • Serial Year
    2013
  • Journal title
    Marine Pollution Bulletin
  • Record number

    1988127