• Title of article

    Optimization study of a transportable neutron radiography unit based on a compact neutron generator

  • Author/Authors

    Panayotis Fantidis، نويسنده , , J.G. and Nicolaou، نويسنده , , G.E. and Tsagas، نويسنده , , N.F.، نويسنده ,

  • Pages
    5
  • From page
    331
  • To page
    335
  • Abstract
    A transportable fast and thermal neutron radiography system, incorporating a compact DD neutron generator, has been simulated using the MCNPX code. The materials considered were compatible with the European Union Directive on ‘Restriction of Hazardous Substances’(RoHS) 2002/95/EC, hence excluding the use of cadmium and lead. Appropriate collimators were simulated for each of the radiography modes. With suitable aperture and collimator designs, it was possible to optimize the parameters for both fast and thermal neutron radiographies, for a wide range of values of the collimator ratio. The system simulated allows different object sizes to be studied with a wide range of radiography parameters.
  • Keywords
    Fast neutron radiography , MCNP , RoHS Directive , Thermal neutron radiography
  • Journal title
    Astroparticle Physics
  • Record number