Title of article
Optimization study of a transportable neutron radiography unit based on a compact neutron generator
Author/Authors
Panayotis Fantidis، نويسنده , , J.G. and Nicolaou، نويسنده , , G.E. and Tsagas، نويسنده , , N.F.، نويسنده ,
Pages
5
From page
331
To page
335
Abstract
A transportable fast and thermal neutron radiography system, incorporating a compact DD neutron generator, has been simulated using the MCNPX code. The materials considered were compatible with the European Union Directive on ‘Restriction of Hazardous Substances’(RoHS) 2002/95/EC, hence excluding the use of cadmium and lead. Appropriate collimators were simulated for each of the radiography modes. With suitable aperture and collimator designs, it was possible to optimize the parameters for both fast and thermal neutron radiographies, for a wide range of values of the collimator ratio. The system simulated allows different object sizes to be studied with a wide range of radiography parameters.
Keywords
Fast neutron radiography , MCNP , RoHS Directive , Thermal neutron radiography
Journal title
Astroparticle Physics
Record number
1991445
Link To Document