• Title of article

    An improvement to the full-foil mapping technique for high accuracy measurement of X-ray mass attenuation coefficients

  • Author/Authors

    Rae، نويسنده , , Nicholas A. and Glover، نويسنده , , Jack L. and Chantler، نويسنده , , Christopher T.، نويسنده ,

  • Pages
    4
  • From page
    47
  • To page
    50
  • Abstract
    The limiting uncertainty in recent high accuracy measurements of the mass attenuation coefficient is the measurement of the integrated column density. An improvement in the design of the absorption foil holder is described which reduces the integrated column density uncertainty. The new design allows the edges of the foil to be more accurately mapped by the X-ray beam by reducing the largest source of uncertainty in the foil mapping: the uncertainty in the points along the foil edge. The method is shown to reduce the uncertainty in measurements of the mass attenuation coefficient of zinc foils. The reduced uncertainty in the full-foil mapping will allow the X-ray Extended Range Technique (XERT) to be applied to small non-metallic absorption foils more accurately.
  • Keywords
    Atomic form-factor , XERT , X-ray mass attenuation coefficient
  • Journal title
    Astroparticle Physics
  • Record number

    1991471