• Title of article

    Photodiodes selection for the VIRGO detector the first step

  • Author/Authors

    Caron، نويسنده , , B and Dominjon، نويسنده , , A and Flaminio، نويسنده , , R and Hermel، نويسنده , , R and Lacotte، نويسنده , , J.C and Marion، نويسنده , , F and Massonet، نويسنده , , L and Morand، نويسنده , , R and Mours، نويسنده , , B and Verkindt، نويسنده , , D and Yvert، نويسنده , , M، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1995
  • Pages
    6
  • From page
    379
  • To page
    384
  • Abstract
    In the framework of the gravitational waves detector VIRGO, we are developing the photo detectors system. The diodes we will use must satisfy at the same time quite unusual criteria, among them a good quantum efficiency at a wavelength of 1.06 μm and a good linearity at MHz frequencies for an incident light power of 100 mW. We present here the test method and the first very promising results we obtained towards these directions with commercially available diodes in InGaAs.
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1995
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number