Title of article
Experiences with the narrow gap undulator at MAX-lab
Author/Authors
Andersson، نويسنده , , إ. and Werin، نويسنده , , S. and Meinander، نويسنده , , T. and Naves de Brito، نويسنده , , A. and Aksela، نويسنده , , S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1995
Pages
6
From page
586
To page
591
Abstract
An undulator with short poles (period 24 mm) and extremely narrow gap (magnet gap 7.7 mm) using a squeezable vacuum chamber has been installed and is in operation at the MAX-lab 550 MeV storage ring. The device operates with a vacuum chamber aperture down to 6.2 mm. The behaviour of the storage ring concerning lifetime, emittance, tune shift and closed orbit is well described by conventional models. We present here the design of the device, the influence on the storage ring and the spectral characteristics, as well as comparison with expected theoretical results and an overview of the activities at the beam line.