• Title of article

    Tests of photon-detection devices in strong magnetic fields

  • Author/Authors

    Fujii، نويسنده , , Y and Ishii، نويسنده , , K and Kakiguchi، نويسنده , , Y and Kawagoe، نويسنده , , K and Nakamura، نويسنده , , I and Nozaki، نويسنده , , M and Takeda، نويسنده , , H and Takeshita، نويسنده , , T and Yamaoka، نويسنده , , Y and Yokoyama، نويسنده , , C، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1995
  • Pages
    5
  • From page
    71
  • To page
    75
  • Abstract
    Three types of photon-detection devices (FMPMT, HPMT, and VAPD) were tested in strong magnetic fields. The maximum strength of the magnetic field applied in the test was 2.5 T for the FMPMT and HPMT, and 1.0 T for the VAPD. We measured the dependence of the gain on the magnetic-field strength as well as on the angle between the device axis and the magnetic field.
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1995
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number