Title of article
Calibration of the energy analyzing magnet of the NSC Pelletron using a differential time of flight technique
Author/Authors
Sarkar، نويسنده , , A. and Ghosh، نويسنده , , S. and Joshi، نويسنده , , R. and Kanjilal، نويسنده , , D. and Roy، نويسنده , , Marcos A. and Bhowmik، نويسنده , , R.K.، نويسنده ,
Pages
4
From page
351
To page
354
Abstract
A differential time of flight technique was tried using two cavity resonators (as timing devices) for the calibration of the energy analyzing magnet of the pelletron accelerator at NSC. This method is unique as it compensates for the intrinsic delays for the detectors used in other TOF experiments. The experimentally measured value of the radius of curvature of the analyzing magnet is 1808 mm which is comparable to the value obtained from the energy calibration by compound nuclear resonance in the 12C (p,p′) reaction.
Journal title
Astroparticle Physics
Record number
1997424