Title of article
Data analysis in β-spectroscopy with cryogenic detectors
Author/Authors
Fontanelli، نويسنده , , F. and Galeazzi، نويسنده , , M. and Gatti، نويسنده , , F. W. Swift، نويسنده , , A.M. and Vitale، نويسنده , , S.، نويسنده ,
Pages
7
From page
464
To page
470
Abstract
In the environment of the “Manu” experiment for the electron anti-neutrino mass determination with microcalorimeters, we developed a full system to analyze data and extract sensible results. Here we report on data simulation and analysis. We show that, with a single detector with the energy resolution we obtained up to now (15 eV RMS) and a rate of 1 Hz, we may put an upper limit to the electron anti-neutrino mass of the order of 20 eV at 95% C.L. in three months of data taking.
Keywords
?-spectroscopy , Neutrino mass , Micro-calorimeters , Data analysis
Journal title
Astroparticle Physics
Record number
2007931