• Title of article

    Pretreatment of garlic powder using sweep frequency ultrasound and single frequency countercurrent ultrasound: Optimization and comparison for ACE inhibitory activities

  • Author/Authors

    Ma، نويسنده , , Haile and Huang، نويسنده , , Liurong and Peng، نويسنده , , Lei and Wang، نويسنده , , Zhenbin and Yang، نويسنده , , Qiaorong، نويسنده ,

  • Pages
    7
  • From page
    109
  • To page
    115
  • Abstract
    The sweep frequency ultrasound (SFU) and single frequency countercurrent ultrasound (SFCU) pretreatments were modeled and compared based on production of angiotensin I-converting enzyme (ACE) inhibitory peptides from garlic hydrolysates. Two mathematical models were developed to show the effect of each variable and their combinatorial interactions on ACE inhibitory activity. The optimum levels of the parameters in SFU were determined using uniform design, which revealed these as follows: total ultrasonic time 1.5 h, on-time of pulse 18 s and off-time of pulse 3 s. Under optimized conditions, the experimental values of SFU and SFCU were 65.88% and 67.78%, which agreed closely with the predicted values of 63.44% and 67.33%. The SFU and SFCU pretreatments both resulted in higher ACE inhibitory activity compared with untreated garlic (p < 0.05). However, there were no significant differences in the ACE inhibitory activities and IC50 values obtained from SFCU and SFU pretreatments under optimum conditions (p > 0.05).
  • Keywords
    Sweep frequency ultrasound , Single frequency countercurrent ultrasound , garlic , ACE inhibitory activity
  • Journal title
    Astroparticle Physics
  • Record number

    2008336