Title of article
Modeling-based optimization study for an EDXRD system in a portable configuration
Author/Authors
Peterzol، نويسنده , , Angela and Duvauchelle، نويسنده , , Philippe and Kaftandjian، نويسنده , , Valérie and Ponard، نويسنده , , Pascal، نويسنده ,
Pages
14
From page
450
To page
463
Abstract
Energy-Dispersive X-ray Diffraction (EDXRD) is well suited for the detection of narcotics and a wide range of explosives. This technique, combined with the dual-energy tomosynthesis, has been used for verification of a novel portable imaging system, the aim of which is characterization of dangerous/illicit materials inside objects. We present the design methodology and optimization study using EDXRD modality. In order to evaluate the experimental conditions best suited for system purposes, kinematic theory of diffraction has been exploited to model the height and shape of diffraction patterns. From the simulation-based analysis a diffraction angle of 2.75°±0.10° and an X-ray tube voltage ≤160 kV have been selected.
Keywords
Energy-dispersive X-ray diffraction , Deterministic simulation , Nondestructive Testing
Journal title
Astroparticle Physics
Record number
2018135
Link To Document