• Title of article

    A wide dynamic range BF3 neutron monitor with front-end electronics based on a logarithmic amplifier

  • Author/Authors

    Ferrarini، نويسنده , , M. and Varoli، نويسنده , , V. and Favalli، نويسنده , , A. and Caresana، نويسنده , , M. and Pedersen، نويسنده , , B.، نويسنده ,

  • Pages
    5
  • From page
    272
  • To page
    276
  • Abstract
    This paper describes a wide dynamic range neutron monitor based on a BF3 neutron detector. The detector is used in current mode, and front-end electronics based on a logarithmic amplifier are used in order to have a measurement capability ranging over many orders of magnitude. stem has been calibrated at the Polytechnic of Milan, CESNEF, with an AmBe neutron source, and has been tested in a pulsed field at the PUNITA facility at JRC, Ispra. tector has achieved a dynamic range of over 6 orders of magnitude, being able to measure single neutron pulses and showing saturation-free response for a reaction rate up to 106 s−1. It has also proved effective in measuring the PUNITA facility pulse integral fluence.
  • Keywords
    Beam loss monitor , BF3 , Logarithmic amplifier , Pulsed field , Neutron
  • Journal title
    Astroparticle Physics
  • Record number

    2023577