Title of article
Picosecond strain waves in PTV
Author/Authors
Frolov، نويسنده , , S.V and Vardeny، نويسنده , , Z.V.، نويسنده ,
Issue Information
دوماهنامه با شماره پیاپی سال 1997
Pages
2
From page
905
To page
906
Abstract
We studied the propagation of thermo-optically excited transient strain waves in thin films of PTV by means of the ps time-resolved pump-probe technique. We find that ultrasound at high frequencies (above 10GHz) does not properly propagate through the polymer film. Since ultrasound damping is frequency-Independent in the time interval of up to 3ns, we speculate that disorder-induced localization may be responsible for the high frequency cut-off.
Keywords
Photoinduced absorption , time-resolved ultrafast spectroscopy , transient strain waves