Title of article
Studies of poly(o-aminophenol) by quartz crystal impedance measurements
Author/Authors
Ortega، نويسنده , , J.M.، نويسنده ,
Issue Information
دوماهنامه با شماره پیاپی سال 1998
Pages
4
From page
81
To page
84
Abstract
Conducting poly(o-aminophenol) films deposited on Pt electrodes were studied by quartz crystal impedance. The number of molecules of water per poly(o-aminophenol) equivalent in its oxidized form was determined to be approximately seven. As reduction proceeds, swelling of the film takes place but it still exhibits rigid features which make it suitable to analyse by the quartz crystal microbalance. Results show a slightly more rigid polymer at higher concentration of electrolyte and it was established that about 60% of the polymer film is electrochemically oxidized.
Keywords
Quartz crystal impedance measurements , Poly(o-aminophenol)
Journal title
Synthetic Metals
Serial Year
1998
Journal title
Synthetic Metals
Record number
2071919