Title of article
Fabrication and formation of bioactive anodic zirconium oxide nanotubes containing presynthesized hydroxyapatite via alternative immersion method
Author/Authors
Wang، نويسنده , , Lu-Ning and Luo، نويسنده , , Jing-Li، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
7
From page
748
To page
754
Abstract
Hydroxyapatite (HA) coating has been widely applied on metallic biomedical implants to enhance their biocompatibility. It has been reported that HA coating can be formed on annealed zirconium with anodic zirconium oxide nanotubular arrays after immersion in simulated biological fluid (SBF) for about 14 days. In the present study, we apply an alternative immersion method (AIM) to form presynthesized HA on ZrO2 nanotubes. The AIM-treated specimen was then moved to the SBF to evaluate the capability for the formation of HA on it. The HA coating formed after only 2 days immersion and thickened after 5 days in the SBF. The HA coating is the carbonated HA with a ratio of Ca to P of about 1.4, similar to the physiological HA containing other minor elements such as Mg and Na. The results demonstrate that the AIM treatment is indeed suitable for the zirconium oxide nanotubes and highly accelerates the formation of HA coating in comparison with the existing methods, i.e. the annealing of the as-formed zirconium oxide nanotubular arrays.
Keywords
Nanotube , Bioactivity , Anodization , Hydroxyapatite , Zirconium oxide
Journal title
Materials Science and Engineering C
Serial Year
2011
Journal title
Materials Science and Engineering C
Record number
2101259
Link To Document