• Title of article

    Damage assessment in an Al/SiC composite during monotonic tensile tests using synchrotron X-ray microtomography

  • Author/Authors

    Buffiere، نويسنده , , J.-Y. and Maire، نويسنده , , E. and Verdu، نويسنده , , C. and Cloetens، نويسنده , , P. and Pateyron، نويسنده , , M. and Peix، نويسنده , , G. and Baruchel، نويسنده , , J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    3
  • From page
    633
  • To page
    635
  • Abstract
    High resolution X-ray tomography is used to study the evolution of damage in an Al/SiC composite during monotonie tensile tests at room temperature. Two main damage mechanisms are observed when the plastic regime is reached: (i) The cracking of the matrix on brittle oxides resulting from the processing of the material; (ii) the cracking of SiC particles. The aspect ratio of the broken particles along the tensile direction is found to be high and the damage accumulation rate is different at the surface and in the bulk of the material. Those results are discussed with respect to the resolution of the imaging technique and to the strain level reached during the tests.
  • Keywords
    Metal matrix composite , X-ray computed tomography , Damage
  • Journal title
    MATERIALS SCIENCE & ENGINEERING: A
  • Serial Year
    1997
  • Journal title
    MATERIALS SCIENCE & ENGINEERING: A
  • Record number